An OTR figure without its test conditions is close to meaningless. Three variables change the number dramatically.
1. Relative humidity
This is the biggest one. EVOH is hygroscopic — absorbed water plasticises the polymer and the barrier collapses. The same film that passes 0.2 cm³/m²·day at 0 % RH might pass 2 at 65 % RH and considerably more at 85 % RH. Always ask for the figure at the humidity your product actually lives in.
2. Gauge normalisation
Barrier scales inversely with thickness. A figure quoted for 25 μm does not apply to a 50 μm film. Ask whether the number is "as supplied" or "normalised to 25 μm" — and compare like with like.
3. Units
Mil versus micron is the classic trap. 20 μm is roughly 0.8 mil. The same film quoted in mil units produces a different-looking number, and some suppliers quote in whichever unit makes the figure look better.
Test method
ASTM D3985 is the oxygen standard; ASTM F1249 is the water standard. ISO equivalents exist. Two labs testing the same film under the same nominal conditions can report meaningfully different figures, because "65 % RH" and "23 °C" describe a controlled chamber, not a single point.
What to do with this
Compare at the same conditions, on the same gauge basis, and ideally with the same standard. Then add margin: your shelf life claim needs to survive the worst condition in your distribution chain, not the average one.